Heat Flux Density Converter
Convert between heat flux density units including Watts per square meter and BTU per hour square foot.
Result
1 W/m² = 0.001 kW/m²
Understanding Heat Flux Density Units: Watt to Kilowatt and Thermal Transfer Rate
Heat flux density converters are essential tools for calculating instantaneous thermal power transfer per unit area, measuring irradiance, solar intensity, and thermal loading rates. Whether you're working with watts per square meter (W/m²), kilowatts per square meter (kW/m²), watts per square centimeter (W/cm²), watts per square inch (W/in²), calories per second per square centimeter (cal/(s·cm²)), British thermal units per hour per square foot (Btu/(h·ft²)), horsepower per square foot (hp/ft²), or any of twenty-six thermal flux density units, understanding heat flux density conversions is crucial for engineers, scientists, and analysts in solar energy, HVAC, materials science, thermal protection, and energy efficiency industries.
Heat flux density measurements quantify the rate of thermal energy transfer per unit area, representing instantaneous power flux rather than cumulative energy. From solar irradiance at 1000 W/m² (1 kW/m²) reaching Earth's surface to industrial heating at 10-50 kW/m², and from building heat loss at 5-20 Btu/(h·ft²) to laser processing at 10⁶-10⁷ W/m², this comprehensive converter supports twenty-six thermal flux density units with instant, accurate results for all your heat transfer, solar energy, and thermal design calculations across different measurement systems.
How to Convert Heat Flux Density Units: Formulas and Methods
Watt per Square Meter to Kilowatt Conversions
Converting from watts per square meter (W/m²) to kilowatts per square meter (kW/m²) divides by 1000, since 1 kW/m² equals 1000 W/m². For example, solar irradiance of 1000 W/m² equals 1 kW/m². Converting to watts per square centimeter (W/cm²) divides by 10000, since 1 m² equals 10,000 cm², so 1000 W/m² equals 0.1 W/cm². Converting to watts per square inch (W/in²) divides by 1550, since 1 m² equals approximately 1550 in², making 1000 W/m² equal to 0.645 W/in².
Calorie-Based Heat Flux Density Units
Converting from W/m² to calorie IT per second per square centimeter (cal(IT)/(s·cm²)) divides by 41840, since 1 cal(IT)/(s·cm²) equals 41840 W/m². For minute-based units, cal(IT)/(min·cm²) equals 697.33 W/m² (divide by 60), and for hour-based units, cal(IT)/(h·cm²) equals 11.622 W/m² (divide by 3600). The thermochemical variants (cal(th)) use identical conversion factors: 41840 W/m² for seconds, 697.33 for minutes, and 11.622 for hours.
British Thermal Unit per Square Foot Conversions
Converting from W/m² to Btu IT per hour per square foot (Btu(IT)/(h·ft²)) multiplies by 0.317, since 1 Btu(IT)/(h·ft²) equals 3.15459 W/m². For minute-based units, Btu(IT)/(min·ft²) equals 189.276 W/m², and for second-based units, Btu(IT)/(s·ft²) equals 11356.53 W/m². The thermochemical variants differ slightly: Btu(th)/(h·ft²) equals 3.15247 W/m², Btu(th)/(min·ft²) equals 189.147 W/m², and Btu(th)/(s·ft²) equals 11348.8 W/m², reflecting the small Btu definition difference.
Horsepower and Mechanical Power Units
Converting from W/m² to horsepower per square foot (hp/ft²) divides by 8007.37, since 1 hp/ft² equals 8007.37 W/m² (1 hp = 745.7 W, 1 ft² = 0.092903 m²). For metric horsepower, hp(metric)/ft² equals 7887.24 W/m² (1 metric hp = 735.5 W). Foot-pound per minute per square foot (ft·lbf/(min·ft²)) equals 0.225 W/m², representing mechanical work-based heat flux. These units appear in engine design, power density calculations, and mechanical heat generation applications.
Heat Flux Density Versus Heat Density
Heat flux density (W/m², Btu/(h·ft²)) measures instantaneous power per area, while heat density (J/m², Langley, Btu/ft²) measures cumulative energy per area. Heat density equals heat flux density integrated over time: J/m² = W/m² × seconds. For example, 1000 W/m² solar flux for 1 hour equals 3.6×10⁶ J/m² or 86.1 Langleys. Conversion factors differ because flux represents rate while density represents total accumulated energy over time.
Heat Flux Density Conversion Reference Table
| W/m² | kW/m² | W/cm² | cal(IT)/(s·cm²) | Btu(IT)/(h·ft²) | hp/ft² |
|---|---|---|---|---|---|
| 1 | 0.001 | 0.0001 | 0.000024 | 0.317 | 0.000125 |
| 100 | 0.1 | 0.01 | 0.0024 | 31.7 | 0.0125 |
| 500 | 0.5 | 0.05 | 0.012 | 158.5 | 0.0624 |
| 1000 | 1 | 0.1 | 0.024 | 317 | 0.125 |
| 5000 | 5 | 0.5 | 0.120 | 1585 | 0.624 |
| 10000 | 10 | 1 | 0.239 | 3170 | 1.249 |
| 41840 | 41.84 | 4.184 | 1.000 | 13263 | 5.225 |
| 50000 | 50 | 5 | 1.195 | 15853 | 6.245 |
| 100000 | 100 | 10 | 2.390 | 31706 | 12.490 |
Typical Heat Flux Density Values by Application
| Application | W/m² | kW/m² | Btu/(h·ft²) |
|---|---|---|---|
| Solar irradiance (space) | 1366 | 1.366 | 433 |
| Solar irradiance (Earth surface, clear sky) | 1000 | 1.000 | 317 |
| Solar irradiance (cloudy day) | 100-300 | 0.1-0.3 | 32-95 |
| Building heat loss (wall) | 5-50 | 0.005-0.05 | 1.6-16 |
| Industrial furnace wall | 5000-50000 | 5-50 | 1585-15853 |
| Electronic component (cooling required) | 1000-10000 | 1-10 | 317-3171 |
| Human body (radiative loss) | 50-100 | 0.05-0.1 | 16-32 |
| Laser cutting | 10⁶-10⁷ | 1000-10000 | 3.17×10⁵-3.17×10⁶ |
Industry Applications and Use Cases
Solar Energy and Photovoltaic Systems
Solar engineers use heat flux density in W/m² or kW/m² to measure solar irradiance, evaluate photovoltaic panel performance, and calculate energy generation potential. Converting between W/m², kW/m², and Btu/(h·ft²) enables comparing international solar resource data and system specifications. Typical values range from 100 W/m² on cloudy days to 1000 W/m² (1 kW/m²) under clear skies, representing instantaneous solar power available for conversion.
HVAC and Building Energy Performance
HVAC professionals convert between W/m² and Btu/(h·ft²) when calculating heat loss through building envelopes, sizing heating/cooling systems, and evaluating thermal performance. Typical building heat flux ranges from 5-50 W/m² (1.6-16 Btu/(h·ft²)) through walls and windows. Converting units helps engineers compare international building codes, energy standards, and insulation requirements across different measurement systems.
Industrial Processes and Furnace Design
Process engineers use heat flux density in kW/m² or cal/(s·cm²) to design furnaces, evaluate thermal processing equipment, and calculate heating requirements. Industrial applications range from 5-50 kW/m² for furnace walls to 10⁶-10⁷ W/m² for laser processing. Converting between W/m², kW/m², Btu/(h·ft²), and hp/ft² enables comparing equipment specifications and thermal design parameters across international manufacturers.
Electronic Cooling and Thermal Management
Electronics engineers calculate heat flux density in W/m² or W/cm² to design cooling systems, evaluate thermal performance, and prevent component overheating. Modern processors generate 1000-10000 W/m² requiring active cooling. Converting between W/m², W/cm², and Btu/(h·ft²) helps engineers size heat sinks, fans, and liquid cooling systems when working with international component specifications and thermal design standards.
Frequently Asked Questions
What is heat flux density and how does it differ from heat density?
Heat flux density (W/m², Btu/(h·ft²)) measures instantaneous power transfer per unit area, while heat density (J/m², Langley) measures cumulative energy per unit area over time. Heat flux represents rate of transfer, while heat density represents total accumulated energy. Heat density equals heat flux integrated over time.
How do I convert W/m² to kW/m²?
Divide W/m² by 1000 to get kW/m², since 1 kilowatt equals 1000 watts. For example, solar irradiance of 1000 W/m² equals 1 kW/m², and a furnace wall at 50000 W/m² equals 50 kW/m² for convenient large-scale values.
How to convert W/m² to W/cm²?
Divide W/m² by 10000 to get W/cm², since 1 square meter equals 10,000 square centimeters. For example, 1000 W/m² equals 0.1 W/cm², and 41840 W/m² equals 4.184 W/cm² for high-intensity applications like laser processing.
How to convert W/m² to Btu/(h·ft²)?
Multiply W/m² by 0.317 to get Btu(IT)/(h·ft²), since 1 Btu(IT)/(h·ft²) equals 3.15459 W/m². For example, 1000 W/m² equals 317 Btu/(h·ft²), and building heat loss of 50 W/m² equals 15.8 Btu/(h·ft²) for HVAC calculations.
What's the difference between Btu IT and Btu th for heat flux?
Btu IT/(h·ft²) equals 3.15459 W/m² while Btu th/(h·ft²) equals 3.15247 W/m² - a 0.067% difference due to different Btu definitions. International Table Btu (1055.06 J) versus thermochemical Btu (1054.35 J) affects conversion precision. Use IT for general engineering and th for thermodynamic applications.
How to convert to horsepower per square foot?
Divide W/m² by 8007.37 to get hp/ft², since 1 hp/ft² equals 8007.37 W/m². For example, 8007 W/m² equals 1 hp/ft². Metric horsepower uses 7887.24 W/m² per hp(metric)/ft². These units appear in engine design and power density calculations.
What are typical solar irradiance values?
Solar irradiance ranges from 1366 W/m² (1.366 kW/m²) in space to 1000 W/m² at Earth's surface under clear skies, down to 100-300 W/m² on cloudy days. Converting to Btu/(h·ft²): multiply by 0.317, giving 317 Btu/(h·ft²) for clear sky and 32-95 for cloudy conditions.
How is heat flux used in building design?
Building engineers use heat flux in W/m² or Btu/(h·ft²) to calculate heat loss through walls, windows, and roofs, size HVAC systems, and evaluate thermal performance. Typical values: 5-50 W/m² (1.6-16 Btu/(h·ft²)) through building envelopes. Converting units helps compare international building codes and insulation standards.
How to convert calorie-based heat flux units?
Calorie IT per second per square centimeter equals 41840 W/m². For minutes, divide by 60: 697.33 W/m². For hours, divide by 3600: 11.622 W/m². Thermochemical calories use identical factors. Converting helps compare calorimetric measurements with engineering heat flux data.
How accurate are heat flux conversions?
Our converter uses exact mathematical relationships with 10-decimal precision. W/m² to kW/m²: divide by 1000 exactly. W/m² to Btu(IT)/(h·ft²): multiply by 0.317 exactly (divide by 3.15459). Small differences between Btu IT and Btu th (0.067%) ensure precision for scientific and engineering applications.
What heat flux values are dangerous?
Heat flux exceeding 10-20 kW/m² can cause burns on human skin within seconds. Industrial processes use 5-50 kW/m² for furnaces, while laser cutting operates at 10⁶-10⁷ W/m² (1000-10000 kW/m²). Converting helps evaluate safety limits and thermal protection requirements across different unit systems.
How does heat flux relate to temperature difference?
Heat flux density equals thermal conductivity times temperature gradient: q = k × (ΔT/Δx). Higher temperature differences or better thermal conductivity increase heat flux. Converting heat flux units helps compare heat transfer coefficients and thermal resistances when working with different measurement systems in conduction, convection, and radiation analysis.
Related Unit Converters
Heat Density
Convert heat density units
Thermal Conductivity
Convert thermal conductivity
Thermal Resistance
Convert thermal resistance units
Heat Transfer Coefficient
Convert heat transfer units
Specific Heat Capacity
Convert specific heat units
Energy Converter
Convert energy units
Power Converter
Convert power and wattage
Temperature Converter
Convert absolute temperatures
Thermal Expansion
Convert thermal expansion
Radiation Converter
Convert radiation units